Availability: | |
---|---|
HS-504PTF-2
HUAKE
Principal Properties & Application:
HS-504PTF-2 is a halogen-free, flame-retardant unsaturated polyester resin formulated with flame-retardant additives. It features low smoke emission, is pre-accelerated, and exhibits thixotropic behavior with moderate viscosity. The resin offers excellent handling properties and good anti-settling performance during storage and application.
When reinforced with fiberglass, the cured laminate can meet a range of flame-retardant standards, including TB/T 3138, DIN 5510-2, BS 476 Part 7 (Class 2), and UL94 V-0. It also complies with the material safety and VOC emission requirements commonly applied in rail transit sectors.
Applications:
This resin is ideal for producing halogen-free, low-smoke FRP (fiber-reinforced plastic) components, particularly in hand lay-up processes. Typical applications include construction panels and interior parts for railway passenger vehicles that require stringent flame retardancy and low smoke generation.
Specifications of liquid resin:
Item | Standard Requirements | Test Method |
Appearance | Paste Liquid | GB/T 8237.6.1.1 |
Viscosity(25℃, mPa.s) | 400-600 | GB/T 7193.4.1 |
Gel Time(min) | 10-45 | GB/T 7193.4.6 |
Curing system in SPI test: Hardener AKZO CH-50: 2%;
Physical properties of FRP/Casting(for reference only):
Item | Unit | Test Value | Test Method | |
FRP | Casting | |||
Tensile strength | MPa | 115 | GB/T 1447 | |
Flexural strength | MPa | 181 | -- | GB/T 1449 |
KJ/m2 | 178 | -- | GB/T 1451 | |
Oxygen Index | % | 33 | -- | GB/T 8924 |
45°Angle Burning | -- | flame retardant | -- | TB/T 2402 |
Hardness (Barcol 934-1) | -- | 62 | -- | GB/T 3854 |
HDT | ℃ | -- | 75 | GB/T 1634 |
Attention:
HS-504PTF-2 is a flame-retardant unsaturated polyester resin formulated with functional fillers. Due to the presence of fillers, slight sedimentation may occur over time during storage. To maintain consistent flame-retardant performance, it is essential to stir the resin thoroughly in its container prior to application. For best results, the resin should be used promptly to reduce the impact of extended storage.
|Application:
HS-504PTF-2 is suitable for fiberglass products with halogen-free, low smoke flame retardant requirements, such as hand lay-up molded construction materials and railway passenger car components.
Rail transportation
Cooling Tower
Urban Transit